3.6 THE SENSOR SENSITIVITY
The detectors’ sensitivity can be changed to a high or low(er) value.
1= High
2 = Low
In the high sensitivity mode each detection will provoke an alarm. In the lower sensitivity mode the
alarm will be provoked in case two detections are measured within a time frame of 15 seconds. This
mode prevents false alarms in case of e.g. draught and is most suitable in case the sensor is directed
towards an open space.
3.7 ENTRY DELAY
It is possible to choose from 4 entry delay times. The entry delay is the time between the moment of
detection and the moment of sending the first SMS text message.
Take care: in case the GSM network has a low reach, the time can be longer in case the network
connection was not established within the time of the entry delay.
3.8 ENTRY INDICATION
As factory setting there is no entry indication. It is possible to hear an indication beep during the entry
delay. This can be used as a reminder that the Mobeye is in active mode. It is also possible to let the
LED indicator flash a few times, just as indicator for the user.
3.9 SIREN
After the entry delay, the siren can sound during two minutes. At the same time the SMS text
messages and telephone calls will be done. At soon as the Mobeye is switched off, the siren will stop.
It is possible to test the loud alarm. During the test the siren will be heard until it is cancelled by <OK>
<OK>. This test is also possible in case the Mobeye i110 is programmed as a silent alarm.
3.10 TEMPERATURE ALARM
The Mobeye
®
is able to send a temperature alarm as soon as the actual temperature reaches a
programmed min. or max. level. This function can be used independently of the motion detection. As
soon as the temperature is too high or too low, an SMS text message is sent, followed by a telephone
call. As long as the out of range temperature remains, the report will be repeated hourly. Once the
temperature is back to normal, the Mobeye
®
confirms this to you.
This function is active as soon as a temperature limit is programmed. By resetting the limits, the
function becomes inactive.
3.11 ADJUSTING THE TEMPERATURE
The built-in temperature sensor may have a standard deviation of the actual temperature. In this case,
the deviation will be similar at all temperatures. It is possible to correct the temperature deviation in
the Mobeye i110. In the SMS setting summary, you see the reported temperature. If a correction is
specified, it is processed in the displayed temperature; the correction factor itself is displayed
separately.
Example: Mobeye temperature: 13 C. Actual temperature: 14 C. To correct this deviation, one degree
should be added.
3.12 INTERVAL TEST MESSAGE
The Mobeye
®
can send test messages. Through these test reports you will be ascertained of the
proper functioning of your Mobeye. You can set the interval between the reports indicate the number
of days between reports. This is adjustable between 0 (no test reported) and 30 (monthly test
message). Note: the interval of 1 day will result in a daily test message; the exact time between the
messages will be about 24 hours.
The smaller the interval between the test reports, the shorter is the battery life. The test message only
works if the system is on or a temperature limit is set.